Set Up and Maintain103
The table below gives a denition for all of the elds in the Diagnostics window:
This Field... Shows...
Firmware ID
ID indicating the type of rmware in the lock.
Technical support personnel may ask you to
provide this information.
Version
Version number of the lock’s rmware. Technical
support personnel may ask you to provide this
information.
Diagnostics Code Hexadecimal number indicating rmware
conditions, such as rmware resets, that have
occurred at the lock since the diagnostics code
was last cleared. The code 0x00 means no
conditions have occurred.
To view the meaning of the code, click/tap the
more button (...). The Diagnostics Code window
shows each active diagnostics code and its
meaning. Click/tap the close button (X) to close
the window.
Online Mode Whether the lock is under time zone control
(Automatic) or set to a specic mode, such as
Locked or Unlocked. For more information, see
“Set: Online Mode” on page 82.
Use Count Number of times access was granted since the
use count was last reset. To reset the use count,
see “Reset: Use Count” on page 85.
Main Battery Current power level of the lock’s battery pack.
No shading in the status bar indicates an Alarm
condition. The batteries are dead and must be
replaced. If the shading falls within the Warning
range, the power level is 30% or lower. You
should replace the batteries soon. If the shading
falls within the Good range, the power level is
between 30% and 100%.
Comments to this Manuals